Su'esu'e Chlorine Toe
-
DPD Colorimetry Chlorine Analyzer CLG-6059DPD
DPD Colorimetry Chlorine Analyzer CLG-6059DPDO lenei oloa o le DPD o totoe o le chlorine i luga ole laiga su'esu'e i luga ole laiga na fausia ma gaosia e le matoukamupani. O lenei meafaigaluega e mafai ona fesoʻotaʻi ma PLC ma isi masini e ala i le RS485 (Modbus RTUprotocol), ma ei ai uiga o fesoʻotaʻiga vave ma faʻamaumauga saʻo.Fa'atataugaO lenei su'esu'e e mafai ona otometi ona iloa le fa'aogaina o le chlorine o totoe i le vai i luga ole laiga. Le faatuatuainafaʻaaogaina auala colorimetric DPD a le atunuʻu, ma e otometi lava ona faaopoopo le reagent mofua colorimetric, lea e talafeagai mo le mataituina o totoe chlorine concentration i lefa'agasologa ole chlorination ma fa'amama fa'ama'i ma totonu ole paipa vai inu.Vaega:1) Malosiaga lautele faʻaoga, mamanu mata paʻi.2) DPD colorimetric metotia, o le fua e sili atu saʻo ma mautu.3) Otometi fua ma otometi calibration.4) Ole taimi ole au'ili'ili ole 180 sekone.5) E mafai ona filifilia le vaitaimi fua: 120s~86400s.6) E mafai ona e filifili i le va otometi po'o le tusi lesona.7) 4-20mA ma RS485 gaosiga.8) Faʻamaumauga faʻamaumauga galuega, lagolago U tisiki auina atu i fafo, e mafai ona matamata tala faasolopito ma calibration faamatalaga.Igoa Oloa Su'esu'e Chlorine i luga ole laiga Fa'avae fua DPD colorimetry Fa'ata'ita'iga CLG-6059DPD Fua Fa'atatau 0-5.00mg/L(ppm) Sa'o Filifili le lapo'a o le ±5% tau fua po'o le ±0.03 mg/L(ppm) I'ugafono 0.01mg/L(ppm) Paoa sapalai 100-240VAC, 50/60Hz Tulaga Fa'atusa 4-20mA galuega faatino,Max.500Ω Fesootaiga RS485 Modbus RTU Fa'aaliga Fa'alogo 2 fesoʻotaʻiga ON / OFF fesoʻotaʻiga, faʻatulagaina tutoʻatasi o faʻailoga Hi / Lo, faʻatasi ai ma le faʻaogaina o le hysteresis, 5A / 250VAC poʻo le 5A / 30VDC Teuina o Faamatalaga Fa'amaumauga fa'amaumauga galuega, lagolago U tisiki auina atu i fafo Faaalia 4.3inch lanu LCD fa'aali mata pa'i Fua/Mamafa 500mm * 400mm * 200mm (Uumi * lautele * maualuga); 6.5KG (Leai reagents) Reagent 1000mLx2, e tusa ma le 1.1kg le aofaʻi; e mafai ona faʻaaogaina e tusa ma le 5000 taimi Fua Vaeluaga 120s~86400s; 600s faaletonu Taimi fua tasi E tusa o le 180s Gagana Saina/Igilisi Tulaga Faagaioiga Vevela: 5-40℃
Susū: ≤95%RH (le fa'asa'o)
Filogia: 2
Maualuluga: ≤2000m
Ova malosi: II
Ole fua ole tafe: 1L/min ua fautuainaTulaga o galuega Fa'ata'ita'iga fua faatatau tafe: 250-300mL/min, Fa'ata'ita'iga fa'aoso mamafa:1bar(≤1.2bar)
Fa'ata'ita'iga vevela:5~40℃ -
Initoneti Residual Chlorine Analyzer/Chlorine Dioxide Analyzer
★ Numera Fa'ata'ita'iga: CL-2059B
★ Fa'amatalaga: 4-20mA
★ Polokalama: Modbus RTU RS485
★ Fua Faatatau: Chlorine Toe/Chlorine Dioxide, Temperature
★ Sapalai Malosiaga: AC220V
★ Faʻaaliga: Faʻafaigofie ona faʻapipiʻi, maualuga maualuga ma laʻititi laʻititi.
★ Fa'aoga: Vai inu ma vai laau ma isi
-
Fa'ainitaneti Residual Chlorine Analyzer Fa'aaogaina Mo Suavai otaota Fa'afoma'i
★ Numera Fa'ata'ita'iga: FLG-2058
★ Fa'amatalaga: 4-20mA
★ Polokalama: Modbus RTU RS485
★ Fua Faatatau: Chlorine Toe/Chlorine Dioxide, Temperature
★ Sapalai Malosiaga: AC220V
★ Faʻaaliga: Faʻafaigofie ona faʻapipiʻi, maualuga maualuga ma laʻititi laʻititi.
★ Fa'aoga: Vai otaota fa'afoma'i, vai otaota fale gaosimea etc
-
Fa'ainitaneti Residual Chlorine Analyzer Fa'aaogaina mo Suavai Inu
★ Numera Fa'ata'ita'iga: CLG-6059T
★ Polokalama: Modbus RTU RS485
★ Fua Fa'atatau: Chlorine Toe, pH ma le Temperature
★ Sapalai Malosiaga: AC220V
★ Fa'aaliga: 10-inisi lanu pa'i fa'aali mata, faigofie ona fa'agaoioia;
★ Faʻapipiʻiina i eletise numera, faʻapipiʻi ma faʻaoga, faʻapipiʻi faigofie ma tausiga;
★ Fa'aoga: Vai inu ma vai laau ma isi
-
Initoneti Residual Chlorine Analyzer
★ Numera Fa'ata'ita'iga: CL-2059S&P
★ Fa'amatalaga: 4-20mA
★ Polokalama: Modbus RTU RS485
★ Sapalai Malosiaga: AC220V poʻo DC24V
★ Features: 1. E mafai e le faiga tuʻufaʻatasia ona fuaina le chlorine ma le vevela o totoe;
2. Faatasi ai ma le pule muamua, e mafai ona faʻaalia le RS485 ma le 4-20mA faʻailoga;
3. Faʻapipiʻiina i eletise numera, faʻapipiʻi ma faʻaoga, faʻapipiʻi faigofie ma tausiga;
★ Fa'aoga: Vai otaota, vai vaitafe, vaita'ele
-
Initoneti Residual Chlorine Analyzer
★ Numera Fa'ata'ita'iga: CL-2059A
★ Fa'amatalaga: 4-20mA
★ Polokalama: Modbus RTU RS485
★ Sapalai Malosiaga: AC220V poʻo DC24V
★ Fa'aaliga: Tali vave, malosi malosi fa'alavelave fa'alavelave
★ Fa'aoga: Vai otaota, vai vaitafe, vaita'ele