Industrial Residual Chlorine, su'esu'e osone fa'amavae

Fa'amatalaga Puupuu:

★ Numera Fa'ata'ita'iga: CLG-2096Pro

★ Fua Fa'atataus: chlorine saoloto, chlorine dioxide, osone fa'amavae

★Fesootaiga Fesootaiga:Modbus RTU(RS485)

★ Sapalai Malosiaga: (100~240)V AC, 50/60Hz (Filifili 24V DC)

★ Fua Fa'avae:Malosiaga faifai pea


  • facebook
  • sns02
  • sns04

Fa'amatalaga Oloa

CLG-2096Pro Online Residual Chlorine Analyzer o se mea faigaluega suʻesuʻe analog i luga ole laiga, e tutoʻatasi e atiina ae ma gaosia e Shanghai BOQU Instrument Co., Ltd. E mafai ona fua saʻo ma faʻaalia le chlorine saoloto (hypochlorous acid ma masima e fesoʻotaʻi), chlorine dioxide, osone i chlorine o loʻo i ai fofo. O lenei meafaigaluega e fesoʻotaʻi ma masini e pei o le PLC e ala i le RS485 (Modbus RTU protocol), lea e iai uiga o fesoʻotaʻiga vave ma faʻamatalaga saʻo. O galuega atoatoa, faʻatinoga mautu, faʻaogaina faigofie, faʻaitiitia le faʻaaogaina o le eletise, saogalemu ma le faʻatuatuaina o tulaga sili ona lelei o lenei meafaigaluega.
O lenei meafaigaluega e faʻaogaina ai le faʻaogaina o le chlorine electrode analog, lea e mafai ona faʻaaogaina lautele i le mataʻituina pea o le chlorine totoe i le vaifofo i totonu o vai laau, gaosiga o meaʻai, fomaʻi ma le soifua maloloina, faʻamaʻi, togafitiga otaota ma isi fanua.

Vaega fa'apitoa:

1) E mafai ona fetaui ma le vave ma le saʻo atoatoa o totoe o le chlorine analyzer.
2) E fetaui lelei mo le faʻaoga malosi ma le tausia fua, sefe tau.
3) Tuuina atu RS485 & lua auala o le 4-20mA galuega faatino

 

Initoneti Residu Chlorine Meter

 

 

FA'AVAE FA'AVANOA

 

Fa'ata'ita'iga:

CLG-2096Pro
Igoa Oloa Initoneti Residual Chlorine Analyzer
Fua Fa'atatau chlorine saoloto, chlorine dioxide, osone fa'amavae
Atigi ABS palasitika
Paoa sapalai 100VAC-240VAC, 50/60Hz (24VDC faitalia)
Fa'aaogāga Malosiaga 4W
Tuuina atu Lua 4-20mA tunnels gaosiga, RS485
Fa'ata'avale Auala e lua (avega aupito maualuga: 5A/250V AC po'o le 5A/30V DC)
Tele 98.2mm * 98.2mm * 128.3mm
mamafa 0.9kg
Fesootaiga Fesootaiga Modbus RTU(RS485)
Avanoa 0~2 mg/L(ppm); -5 ~ 130.0 ℃ (Vaʻai i le masini lagolago mo le fuaina o fua)
Sa'o ±0.2%;±0.5℃
Fua Fa'atatau 0.01
Taui vevela NTC10k / Pt1000
Fuafuaga Taui vevela 0 ℃ i le 50 ℃
I'uga o le vevela 0.1℃
Savili o le tafe 180-500mL/min
Puipuiga IP65
Siosiomaga Teuina -40 ℃ ~ 70 ℃ 0% ~ 95% RH (e le fa'amalieina)
Siosiomaga Galuega -20 ℃ ~ 50 ℃ 0% ~ 95% RH (e le fa'amalieina)

 

Initoneti Residu Chlorine Meter

 

 

 

Fa'ata'ita'iga:

CL-2096-01

Oloa:

Fa'asolo ole chlorine sensor

Va'aiga:

0.00~20.00mg/L

I'uga:

0.01mg/L

vevela galue:

0~60 ℃

Mea fa'alogo:

tioata, mama platinum

So'oga:

PG13.5 filo

Uaea:

5 mita, uaea leo maualalo.

Talosaga:

vai inu, vaita'ele ma isi

  • Muamua:
  • Sosoo ai:

  • Tusi lau savali iinei ma lafo mai ia i matou